archive-gr.com » GR » H » HAMEG.GR

Total: 33

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Spectrum Accessories
    5 m 1 power cable Operator s Manual Robust carrying case HZ540 HZ550 EMV Near Field Probe Set up to 3GHz The HZ540 550 are the ideal toolkits for the investigation of RF electromagnetic fields They are indispensable for EMI pre compliance testing during product development prior to third party testing The sets include 3 or 5 hand held probes with built in preamplifier covering the frequency range from 1 MHz to approx 3000 MHz The probes of the basic set HZ540 include one magnetic field probe one electric field probe and a high impedance probe In addition to the HZ550 features an optional μ magnetic field probe and a passive radiation probe All probe outputs are matched to the 50 Ω inputs of spectrum analyzers or RF receivers HZ547 3GHz VSWR Bridge for HMS1010 HMS3010 This unit is used to measure the voltage standing wave ratio VSWR and the reflection coefficient of a device under test with an impedance of 50 Ω Typical test objects include attenuators terminations frequency switches amplifiers cables and mixers The measurement range is specified from 150 kHz 1GHz 100 kHz 3 GHz Technical specifications temperature range from 10 C to 45 C Frequency range 100 kHz 3GHz Impedance 50Ω Directivity 28 dB 100 kHz 300 kHz 35 dB 300 kHz 1 GHz 30 dB 1GHz 3GHz Reflection loss at DUT port 20dB Insertion loss IN OUT 20 dB 100 kHz 300 kHz IN OUT 18 dB 300 kHz 3 GHz IN DUT 1 7dB DUT OUT 16dB Max Power Dissipation 26dBm Connectors N female Dimensions W x H x D without connectors 150 x 68 x 29 5mm Weight approx 650 g Temperature range 10 C 45 C HZ525 Termination 50 Ω 1W N male to N male 2 ea Carrying case 265 x

    Original URL path: http://hameg.gr/acc/spectrum/spectrum.html (2016-02-09)
    Open archived version from archive


  • test adapters
    Cable for HM8118 for transfomer measurements HZ188 4 Terminal SMD Component Test Fixture 4 Terminal SMD Component Test Fixture for HM8118 included in delivery for evaluation of SMD components HZ809 Test Adapter for Modular System 8000 Test adapter for the testing and repair of insert modules for Modular System Series 8000 outside the mainframe HM8001 2 The module connection terminals in the basic unit are led through 1 to 1

    Original URL path: http://hameg.gr/acc/testadatpters/adapt.html (2016-02-09)
    Open archived version from archive

  • 8000_line
    mΩ 0 1 C Offset Function Relative Value Measurement RS 232 Interface and Software included Mainframe HM8001 2 required for operation HM8018 LCR Meter Measurement Functions L C R Θ Q D Z Basic Accuracy 0 2 5 Measurement Frequencies 100Hz 120Hz 1kHz 10kHz 25kHz Max Resolution 0 001Ω 0 001pF 0 01μH 2 and 4 Wire Measurement parallel and series Mode Mainframe HM8001 2 required for operation HM8021 4 1 6 GHz Universal Counter Measurement Range 0Hz 1 6GHz 10MHz Time Base with 1ppm Stability TCXO Input A Input Impedance 1MΩ Sensitivity 20mV rms Input C Input Impedance 50Ω Sensitivity 30mV rms 8 Digit Resolution for 10s Measuring Time Time Interval Resolution up to 10ps External Gate Input with Option HO801 Mainframe HM8001 2 required for operation HM8030 6 10 MHz Function Generator Frequency Range 50mHz 10MHz Output Voltage up to 10V pp into 50Ω Waveforms Sine Wave Triangle Square Wave Pulse DC Distortion Factor 0 5 up to 1MHz Rise and Fall Time typ 15ns Internal and external Sweep FM with HO801 Surge and short circuit proof Output Mainframe HM8001 2 required for operation HM8040 3 Triple Power Supply Unit 2 x 0 20V 0 5A 1 x

    Original URL path: http://hameg.gr/8000/8000_line.html (2016-02-09)
    Open archived version from archive

  • accessories
    N socket to BNC plug Description N plug with BNC socket Packaging unit 1 piece HZ22 Feed Through Termination 50 Ω 50 Ω feed through termination 1 GHz 2 Watt Description BNC plug BNC socket Packaging unit 1 piece HZ24 Attenuators 50 Ω One set of 50Ω attenuators with 3 6 10 20dB attenuation 1GHz 1 Watt and 1 HZ22 Packaging unit 1 of each HZ26 BNC T Adapter BNC

    Original URL path: http://hameg.gr/acc/adapters/adapters.html (2016-02-09)
    Open archived version from archive

  • test leads
    Test Lead PVC sheathed test lead with test probes and sheathed banana plugs Color black and red Length 1m Packaging unit 1 piece per color HZ16 Test Cable with micro clamps Silicone test lead with BNC plug to miniature clamp probe Packaging unit 1 piece HZ17 Kelvin Test Lead Kelvin test lead 4 wire with test probe 5 pin DIN connector for HM8018 Packaging unit 1 Piece HZ18 Kelvin Test Lead Kelvin test lead 4 wire with gold plated alligator clip 5 pin DIN connector and shielding mass for HM8018 Packaging unit 1 piece HZ19 Test Tweezers Kelvin test lead 4 wire with SMD test tweezers 5 pin DIN connector for HM8018 Packaging unit 1 piece HZ31 Test Cable 50 Ω Test cable 50 Ω BNC to BNC angle connector Length 1 0m Packaging unit 1 piece HZ32 Test Cable Test cable BNC to 4 mm banana plug Length 1 0m Packaging unit 1 piece HZ33 HZ34 Test Cable 50 Ω Test cable 50 Ω BNC to BNC BNC straight plug Length 0 5m HZ33 Packaging unit 1 piece Length 1 0m HZ34 Packaging unit 1 piece HZ33S HZ34S Test Cable 50 Ω Test cable 50Ω BNC to BNC socket

    Original URL path: http://hameg.gr/acc/leads/leads.html (2016-02-09)
    Open archived version from archive

  • probes
    Max Voltage 400V DC peak AC LF compensation 1 Trimmer RF compensation 2 Trimmer Cable length 1 2m Probe factor identification automatically after plugging Measuring category CAT I HZ51 Probe 10 1 Attenuation ratio 10 1 Bandwidth 150MHz Rise time 2 4 ns Input impedance 10 MΩ II 12 pF Max Voltage 600 V DC peak AC LF compensation 1 RF compensation 1 Cable length 1 2 m Measuring category CAT I HZ52 Probe 10 1 Attenuation ratio 10 1 Bandwidth 250MHz Rise time 1 4 ns Input impedance 10 MΩ II 10 pF Max Voltage 600 V DC peak AC LF compensation 1 RF compensation 2 Cable length 1 2 m Measuring category CAT I HZ53 Probe 100 1 Attenuation ratio 100 1 Bandwidth 100MHz Rise time 3 5 ns Input impedance 100 MΩ II 4 5 pF Max Voltage 1200 V DC peak AC LF compensation 1 Cable length 1 2 m Measuring category CAT I HZ154 Probe 1 1 10 1 Attenuation ratio 1 1 Switchable 10 1 Bandwidth 10 100MHz Rise time 35 3 5 ns Input impedance 1 10 MΩ II 82 12 pF Max voltage 10 1 600 V DC peak AC LF compensation 1 at 10 1 RF compensation 2 at 10 1 Cable length 1 2 m Measuring category CAT I HZO10 10 1 250MHz Probe Attenuation ratio 10 1 Bandwidth 250 MHz Rise time 1 4 ns Input impedance 10 MΩ II 15 pF Max Voltage 400 V DC peak AC Measuring category CAT I HZO20 Probe 1000 1 Attenuation ratio 1000 1 Bandwidth 400MHz Rise time 900 ps Input impedance 50 MΩ II 7 5 pF Max Voltage 1000 Vrms LF compensation 1 Trimmer RF compensation 1 Trimmer Cable length 1 3m Probe factor identification automatically after plugging Measuring category CAT II HZO30 Probe 10 1 Attenuation ratio 10 1 Bandwidth 1GHz Rise time 600 ps Input impedance 1MΩ II 0 9 pF Max Input voltage 20 V Input Dynamic Range 8 V Cable length 1 3m Oscilloscope Input Coupling 50Ω HZO40 Differential Probe 10 1 200MHz Technical specifications at 23 C 2 C Bandwidth 200MHz Attenuation ratio 10 1 Rise time 10 90 1 75ns Gain accuracy 1 Max Input Voltage per Input 60V Max Differential Input Voltage DC peak AC 20V Max Common Mode Input Voltage 60V Input impedance Between Inputs 1MΩ II 3 5pF Each Input to Ground 500kΩ II 7pF Output Voltage into 50Ω 2V Offset typical 2mV CMRR typical 80dB at 60Hz 50dB at 10MHz Battery operation 9V battery 6LR61 Battery life typical 7 5h Input for an external power supply USB Power adapter cable 5 9V DC 200mA HZO41 Differential Probes 10 1 800MHz Technical specifications at 23 C 2 C Bandwidth 800MHz Attenuation ratio 10 1 Rise time 10 90 437ps Gain accuracy 2 Max Input Voltage per Input 40V Max Differential Input Voltage DC peak AC 15V Max Common Mode Input Voltage 30V Input impedance Between Inputs 200kΩ II 1pF Each Input

    Original URL path: http://hameg.gr/acc/probes/probes.html (2016-02-09)
    Open archived version from archive

  • cables
    Multimeter Frequency Counters LCR Bridge Power Meter 8kW Modular System Series 8000 Options Accessories Price List Service in Greece Interface Cables HZ72 IEEE 488 GPIB bus interface cable double shielded 90 angle stackable Length 2 0 m Electronic Instruments Power Supplies Vacuum Technology Sputtering PVD Systems Leak Detection Laboratory Cryo Photonics Microscopy Optical Data Loggers Systems Engineering Electro Physiology Educational Instruments norm electronics ltd 18 Voulis st 105 63 Athens

    Original URL path: http://hameg.gr/acc/leads/cables.html (2016-02-09)
    Open archived version from archive

  • pt100
    immersion sensors with a platinum test resistance of PT100 They ensure excellent precision over a broad temperature range The probes are of robust construction waterproof and also suitable for use in air or dusty environments The technical specifications apply for immersion depths of at least 60mm The probe is connected to the measuring instrument either with a 2 pin connection using a grounded plug HZ812 or with a 4 pin connection via a 4 mm banana plug HZ887 The length of the connector cable is 1 2 m for both probes HZ812 is suitable for use in combination with HM8012 HZ887 is suitable for use in combination with HM8112 Technical specifications in accordance with EN60751 formerly IEC751 Probe diameter 4mm Measurement range 50 400 C Accuracy Class A 0 2 of the reading 0 15 C t99 s 12 s time required to display 99 of the temperature change Connection HZ812 Grounded plug 4 mm 1 2 m PVC cable Connection HZ887 4 mm banana plug 1 2 m PVC cable Accuracy HZ812 in combination with HM8012 50 C T 200 C 0 2 of reading 0 25 C 200 C T 400 C 0 2 of reading 0 45

    Original URL path: http://hameg.gr/acc/pt100/pt100.html (2016-02-09)
    Open archived version from archive



  •