  • C&M Engineering S.A.
    to feed natural gas buses NGB of Public Bus Transportation Organisation in the Attica area The stations are environmental friendly with no emissions of hydrocarbons during operation The Ano Liosia station has natural gas overall flow rate of 5 000 Nm3 h with five refueling positions and can serve up to 600 buses per day The Anthousa station has similar capacity with Ano Liosia station 220 barg CNG filling pressure

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/31_CNG/31_CNG_b.html (2016-02-13)
    Open archived version from archive


  • C&M Engineering S.A.
    The border station consists of filter separators metering system control valves station by pass control system ESD system and valves fire protection system security system analyzers and flow control instrument air system nitrogen system electricity supply stand by generation transformer electrical switchgear vent system Building facilities of 1 800 m² total covered area consisting of administration building control station workshop warehouse electrical substation and entrance guardhouse as well as surrounding

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/23_Turkish%20Border/23_Turkish%20Border_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    points which are the Filis Ave Zefiri for the 14 pipeline and the Parsis Str at N Ionia for the 18 pipeline The project also includes 8 block valve stations along the pipelines route two terminal stations 18 and 14 with pig launching receiving facilities cathodic protection system cable for remote control telecommunication and branches with steel pipes 6 and 4 Provided Services Review and comments of contractor s documents

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/34_Attica%20North/34_Attica%20North_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    12 9 MWe and thermal power output about 17 MWth The second station concerns the installation of an electrical and thermal cogeneration plant including two gas engine generator sets using biogas fuel with electrical power output about 4 8 MWe The produced electrical power of both plants will supply the electrical loads of Psyttalia electrical network 2nd phase while the surplus electric energy will be sold to Hellenic Transmission System

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/Psyttalia%20Waste%20Water/Psyttalia%20Waste%20Water_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    sectors out of 90 in total covering the area of whole municipalities in Attica consisting of 1 200 Km of low pressure 4 bar distribution network 33 Km of medium pressure 19 bar distribution network 55 metering and pressure regulating M R stations 19 4 bar with capacity of 5 000 to 10 000 Nm3 h each Provided Services Basic design including site survey finalization of the network route and

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/Sectors%2030/Sectors%2030_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    MWe lignite steam turbine power generation plant including the following building facilities turbine house bunker house boiler house ESP auxiliary building absorber and related building FGD fuel gas desulfurization auxiliary building and preparation building demineralization and chemical laboratories crusher house hydrogen production plant row water storage and pump house FGD electrical building auxiliary boiler house electrical building for ash handling WWTP electrical chemical building heating and chiller water building and

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/330%20MW%20Meliti/330%20MW%20Meliti_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    cycle power plant consisting of three 3 gas turbines and one 1 steam turbine supplied with natural gas heat recovery steam generators gas turbine electrical building steam turbine HRSG electrical building cooling water intake filtration pump station outfall treatment pump station switchgear building demineralized water production storage black start diesel generator building desalination plant industrial waste water treatment demineralized water make up building fuel oil pump station and service station

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/550%20MW%20Lavrio/550%20MW%20Lavrio_b.html (2016-02-13)
    Open archived version from archive

  • C&M Engineering S.A.
    4200 and mild hydrocracker unit U 4000 and the construction of associated interconnecting pipework The revamped FCC unit has an increased capacity of 275 m3 h at 15oC and is capable to produce a 360 oC TBP hydrotreated vacuum gasoil with 95 wt desulphurization and an atmospheric gasoil with less than 350 ppm w w sulphur content The mild hydrocracker unit U 4000 was revamped in order to cover the

    Original URL path: http://cmengineering.gr/Projects%20Html/Energy/Revamping%20Of%20FCC/Revamping%20Of%20FCC_b.html (2016-02-13)
    Open archived version from archive



  •